 AZ900
30 AMP HEAVY DUTY POWER RELAY
FEATURES * * * * 1 Form C contacts, 2 Form C contacts AC and DC coils available UL Class F (155C) molded construction UL, CUL file E44211
CONTACTS
Arrangement Ratings SPDT (1 Form C) DPDT (2 Form C) Resistive load: Max. switched power: 840 W or 12000 VA Max. switched current: 30 A Max. switched voltage: 600 VAC, 28 VDC 30 A at 240 VAC 1.5 HP at 120 VAC 2.0 HP at 240 VAC 3600 VA at 120 VAC / 240 VAC ballast 30 A at 240 VAC Res., 100k cycles 20 A at 600 VAC 30 A at 28 VDC Silver cadmium oxide < 50 milliohms initially (24 V, 1 A voltage drop method)
GENERAL DATA
Life Expectancy Mechanical Electrical Operate Time (typical) Release Time (typical) Dielectric Strength
(at sea level for 1 min.)
Minimum operations 1 x 107 1 x 105 at 30 A 240 VAC Res. 30 msec at nominal coil voltage 30 msec at nominal coil voltage (without suppression) 2200 Vrms contact to contact 2200 Vrms contact to coil 100 megohms min. at 20C, 500 VDC 50% RH DC: > 10% of nominal coil voltage AC: > 20% of nominal coil voltage -45C (-49F) to 80C (176F) AC coil, 30A -45C (-49F) to 115C (239F) DC coil, 30A 227 grams
UL, CUR
Insulation Resistance Dropout Ambient Temperature Operating Weight
Material Resistance
COIL
Power At Pickup Voltage (typical) Max. Continuous Dissipation Temperature Rise Max. Temperature DC: 1.12 mW AC: 6.9 VA DC: 3.3 W at 20C AC: 12.5 VA at 20C 70C at nominal coil voltage (AC) 35C at nominal coil voltage (DC) 155C (311F)
NOTES
1. All values at 25C (77F). 2. Relay may pull in with less than "Must Operate" value. 3. Specifications subject to change without notice.
9/12/05
AZ900
RELAY ORDERING DATA
COIL SPECIFICATIONS - DC Coil
Nominal Coil VDC 6 12 24 48 110 Nominal Coil VAC 6 12 24 120 240 480 Must Operate VDC 4.50 9.1 18.0 36.0 82.5 Must Operate VAC 5.1 10.2 20.4 102.0 204.0 408.0 Max. Continuous VDC 7.8 15.4 32.0 62.6 143.0 Max. Continuous VAC 6.9 13.8 27.6 138.0 276.0 552.0 Nominal Current mA 10% 333 166 83 42 18.2 Nominal Coil Power VA 9.5 9.5 9.5 9.5 9.5 9.5 Coil Resistance 10% 18 72 290 1150 6050 Coil Resistance 10% 0.85 2.85 11.5 295.0 1170.0 4860.0
ORDER NUMBER*
AZ900-1C-6D AZ900-1C-12D AZ900-1C-24D AZ900-1C-48D AZ900-1C-110D
COIL SPECIFICATIONS - AC Coil 50/60 Hz ORDER NUMBER*
AZ900-1C-6A AZ900-1C-12A AZ900-1C-24A AZ900-1C-120A AZ900-1C-240A AZ900-1C-480A
*For double pole version replace `-1C' with `-2C.'
MECHANICAL DATA
WIRING DIAGRAM
8 6 4 7 5 3
1
2
2 Form C
7 5 3
1
2
1 Form C
2 Form C
1 Form C
Dimensions in inches with metric equivalents in parentheses. Tolerance: .010"
9/12/05


▲Up To Search▲   

 
Price & Availability of AZ900-1C-240A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X